1. Equalization
The fl ow of incoming sewage varies by time of day. The Equalization tank balances out peak fl ow events to ensure a steady & homogenized fl ow rate. Physical treatment is on the incoming sewage to remove nuisance debris.
2. Process Zone
Air is continuously added through diffusers to maintain an aerobic environment where suspended bacteria oxidize organics and ammonia. For more stringent effl uent criteria, dentrifi cation and/or phosphorus removal can be incorporated.
3. Membrane Filtration
Mixed liquor is drawn through the MicroClear® membranes, which act as a physical barrier to suspended solids, bacteria, viruses and protozoa.